The Series A810 electronic mass flow controllers are compact, self-contained units designed to indicate and control a set flow rate of gas. They are unaffected by temperature and pressure variations within specified limits. The mechanical layout of the design includes an LCD readout built into the top of the transducer. This readout module is tiltable over 90 degrees to provide optimum reading comfort. The readout is connected by a standard modular plug, and is readily removable and extended for remote reading installations. Units are available in aluminum or stainless steel.
FEATURES
• Rigid metal construction • Maximum operating pressure - 1000 psig. • NIST traceable calibration certification. • Built-in set point control. • Leak integrity 1 X 10 -7 sccm helium. • 0-5 VDC or 4-20mA signals. • Built-in tiltable readout display in engineering units. • Circuit protection. • Totalizer.
Accuracy:
± 1.5% of full scale, including linearity for gas temperatures of 59°F to 77°F and pressures of 5 to 60 psia
Repeatability:
± 0.5% of full scale
Response time:
Generally 2 seconds to within ±2% of actual flow.
Temperature Coefficient:
0.15% of full scale/°C
Pressure Coefficient:
0.01% of full scale/psi
Maxiumum Pressure Drop:
1.06 to 8.0 psid depending on flow range. Maxiumum Pressure Differential 50 psi
Gas and Ambient Tep:
41° to 122°F
Output Signals
Linear 0-5 VDC (1000 ohms min load impedance) or 4-20 mA (0-250 ohms loop resistance)
Transducer Input Power:
12 VDC; 800 mA
Materials in Fluid Contact:
Aluminum units: anodized aluminum, 316 SS, brass, Viton o-rings Stainless steel units: 316 SS and Viton o-rings
Attitude Sensitivity:
No greater than +15 degrees from horizontal to vertical: Standard calibration is in horizontal position.
Connections:
1/4" Compression Fittings
Leak Integrity:
1 X 10 -7 sccm of helium maximum to the outside environment